Overview the normally open pneumatic control valve is held open by high pressure water force and requires air pressure to close. The reseal pressure range would be 16 to 20 psig 1. Swing check valves installation instructions models 78 flomatic corporation flomatic corp, 15 pruyns island, glens falls, new york 12801 phone. Standard figure 59, 159 and 259 with brass to brass seating not available above 12. The swing check valve is manufactured with a ductile iron body, brass seat, and a. Check valve used for foam water system should be made of corrosionresistant materials equal to brass. Kitz bronzebrass valves are exclusively produced in modern factories used for valve manufacturing. Ezflos brass swing check valve keeps fluids from ezflos brass swing check valve keeps fluids from backing up into the water supply and prevents backflow from wells and boiler systems.
Threaded seat rings are machined with right hand threading and can be removed from body. Bronze to bronze seating is not available in sizes. Standard with screw connections, standard with flange connections. They are classified as oneway directional valves meaning they have two openings in the body, one for fluid to enter and the other for fluid to leave. Easy online ordering for the ones who get it done along with 247.
Apparatus valves elkhart brass fire fighting equipment. Fulflo vseries hydraulic bypass relief valves come in 5 types. Nov 08, 2016 preventative maintenance is pretty standard for pumps, but what about valves. If you skimp on maintenance, youll be faced with sudden failures and unexpected replacement costs.
The sharkbite check valve is a general purpose, the sharkbite check valve is a general purpose, spring loaded check valve that can be installed in seconds on copper cts cpvc and pex. Plumbing maintenance checklist perform an indepth leak check throughout your home. We also do a large range of duck bill check valves which we make to order so please contact us for pricing and information on this. When the actuator output shaft and the valve stem are connected, check that the holes of the valve flange match the holes of the actuator mounting flange. You should have a clear picture of the types of systems your valves were made for, and youll need to know the physical properties of your valves. But what type of valve maintenance program should you choose. Swing checks may be installed in horizontal positions or vertical with flow moving up. This check valve is lead free and suitable for all potable water supply installations.
Remove the valve from the system and place it securely in a vice. Reseal pressure is defined as the downstream pressure at which the check valve closes bubbletight. Wafer check valves reduce the effect of water hammer fm approved for such service. July, 2016 specifications for swl swing check valves general. Brass scorpion electric 839404 installation, operation, and maintenance instructions. Check valves shall be ductile iron body, bronze and stainless mounted, full opening swing type. Sanitary standards the checkall style 3s check valve is compliant with 3a sanitary. It is constructed of brass for strength and durability. For the proper maintenance of your installed check valve, it is always best to follow the recommendations of the manufacturer especially where repairs or replacements are involved.
For a proper installation of the valve, near curves and circulation pumps, the. To remove and replace check valve seats reliably and in a costeffective manner, the valve repair vendor must utilize custom tooling, procedures. Test out shutoff valves on water supply lines under fixtures. For the proper maintenance of your installed check valve, it is always best to follow the recommendations of the manufacturer especially where repairs or replacements are. Operation and maintenance manual for kitz carbon steel, low alloy steel, stainless steel and nickel based alloy gate, globe and check valves flanged, butt welding, threaded and socket welding ends thank you for having chosen kitz products. This valve is not designed to handle impacts of any kind. Check valves are mechanical devices that are subject to fouling, wear and mineral deposits. Install check valve in an accessible location with ample clearance so inspection and maintenance of the check valve can be easily accomplished. Looking for campbell check valve, 1, single, inline spring, brass, fnpt x fnpt 36y048. Installation,operation and maintenance manual swing check valve 3 3 general instructions for transportation, unpacking and storage when suspending and supporting a valve, take care and do not stand under a suspended valve. Abstract plant reliability and safety hinges on the proper functioning of several check valves. Tighten the packing gland to the appropriate torque for the valve.
Swing check valve swing check valve manufactured in compliance with ansiawwa c512 date. The viking swing check valve is a general purpose rubberfaced check valve approved for use in fire protection systems. Installation must be performed by qualified, licensed personnel only. Check valves, filters and relief valves catalog 45cv december 2010. Utilizing this special tooling, craft personnel have performed numerous successful seat replacements on check valves, ranging in size from 12inch nps to 50inch nps. Operating instructions a2600 series awwa swing check. Overview the normally open pneumatic control valve is held open by high pressure water force and requires air pressure to.
Campbell check valve, 1, single, inline spring, brass. The answer is that theres no one right answer to this question. The sharkbite check valve can be installed horizontally or vertically and prevents the reverse flow of water through the water supply line. Mueller a2600 series awwa swing check valves are selfcontained. Different types of valves with pdf file engineering. Operating instructions a2600 series awwa swing check valve. Failure to follow these procedures will cause damage to the stem. When the air supply is interrupted, the valve stem remains in the open position and does not seal the valve seat, allowing the release of stored water. Threaded we appreciate your purchasing our products. Options include inline, bunan seat, threaded and sweat, and more. Check valves, filters and relief valves parker hannifin. For safe and troublefree function and performance of the product. Checkall products are designed, manufactured and distributed in accordance with iso 9001 requirements. Inspection and maintenance are critical for continued operation.
Preventative maintenance is pretty standard for pumps, but what about valves. Kitz bronze and brass gate, globe and check valves. Service and maintenance the following procedures are used for servicing the normally open and normally closed pneumatic control valves. Lv985swlf lf thermostatic mixing valves leonard valve. The lcv1 is a bronze lift check valve, which is designed for installation in. Flow control check valves catalog 3900 check valves c series performance curves general description series c check valves permit free flow in one direction, and dependable shutoff in the reverse direction.
In todays environment of shorter outage windows and shrinking maintenance budgets, the maintenance team should explore all available options when faced with a decision to repair or replace a valve. That means when you order checkall valve products you are assured of receiving the highest quality check valves. Check valves are mechanical devices that permit liquids and gases to flow in only one direction, preventing flow from reversing. Crane supply is in a unique position to provide customers expert technical advice on all types of valves and their application. Standard with screw connections, standard with flange connections, stainless steel with screw connections, handwheel with screw connections, and handwheel with flange connections in a choice of brass, cast iron, steel, and stainless steel. Valve body shall be enlarged to allow disc to swing in the waterway. These include piston check valves, swing check valves and duo check valves. Flow control check valves catalog 3900 check valves c series performance curves general description series c check valves permit free flow in one direction, and dependable shutoff in the. Maintenance of check valves check valves require little attention over long periods of time. Over the past decade, the nuclear industry check valve group nic, industry organizations, non. If yours is not pictured, please contact technical support.
Installationoperationmaintenance awwa swing check valve. The expertise our company can draw from relating to correct valve selection is second to none in the distribution. It features a primary check valve utilizing a rubber disc seating against a mating rubber part to ensure tight. Install the actuator onto the valve without forcing, using only the weight of the actuator. Thermostatic water mixing valve with 10 gpm 269 lmin minimum flow capacity, 2 inlets, 2 outlet 51 mm x 51 mm, integral combination checkstops with strainers, 125 psi 8. Learning how each valve type works will help you design a valve maintenance program for your facility. Installation instructions for cambridge brass check valves. The model 78 swing check does not require any regular maintenance.
By continuing to navigate without changing the settings on your. Maintenance and cleaning of brass instruments by toby shucha your brass instrument may seem like just a hunk of cold metal, but when treated with tender, loving care, it should provide you with many, many years of good performance and much joy. The check valves described in this manual are not to be used as foot valves on a pump or pressure regulating devices. Process systems has a large range of high quality check valves held in stock in australia. To remove and replace check valve seats reliably and in a costeffective manner, the valve repair vendor must utilize custom tooling, procedures and techniques. Normally, the check valve closes under the action of the spring force on the left. Swing check valves installation instructions models 78 flomatic corporation flomatic corp, 15 pruyns island, glens falls, new york 12801. Cleaning the check valve to begin, match the brew group used by your machine with one pictured below. Brass service valves of series ssv are applicable for split air conditioners to connect indoor unit and outdoor unit. Inspection of valve during operation is recommended so that outside linkage can be inspected for proper operation.
It can also be used in other cooling or refrigeration systems. Whether you prefer traditional valves, or a more versatile option like our popular unibody apparatus valve, exceptional design and engineering are your assurance youll find the right. For a valve with a spring having a rated cracking pressure of 25 psig 1. Typea typec typeb typed now, find the page below with the directions specific to. Installation and maintenance guidelines for nibco bronze swing. Swing check valves installation instructions flomatic valves. Preventative maintenance for valves crane engineering. Bronzebrass valves 01 as a world leader in the manufacture of general service valves, kitz corporation is glad to offer a broad range of kitz bronzebrass valves for commercial and industrial applications. Increased knowledge of valve design, construction, and function which in turn will improve workmanship, efficiency, and enhance the troubleshooting efforts.
Series 9d is suitable for use on hot or cold water and can be used under continuous pressure. Check inside the valve to be sure that any materials used in. Pneumatic control valves service and maintenance procedures 10181402 82008rev 24 2 figure 2. See why matconorca is the goto source for your wholesale brass check valve and brass foot valve needs.
Manuals downloads elkhart brass fire fighting equipment. Selection check valves are for the prevention of backflow. The swing check valve is manufactured with a ductile iron body, brass seat, and a rubberfaced clapper assembly, hinged to a removable access cover for easy inspection and maintenance. Operation and maintenance manual for kitz carbon steel, low alloy steel, stainless steel and nickel based alloy gate, globe and check valves flanged, butt welding, threaded and socket welding ends. A preventative maintenance program will directly improve the performance and. Check any visible pipes and joints for signs of corrosion. For operating and maintenance instructions, wiring schematics and other manuals, browse this complete list. As part of the crane valve group, crane supply is the exclusive distributor of. For our installation, operation and maintenance manual and the most current product information go to state of california prop 65 warning. Check valve used for salt water should be made of materials suitable for that purpose and selected from materials specified in bs 1868 section 3. Operation when pressure going through the valve is increased to the cracking level the valve opens.
This is because different products are made of different materials and parts. Outside lever check valves may be fitted with a limit switch to detect flow. Verify that the check valve maintenance kit being used is appropriate for the valves size, the seal material, the. C series check valve maintenance instructions parker hannifin. Disc opens in the direction of flow and returns back on body seat when flow stops and seals with seat ring against backpressure. If not, use the manual override to rotate the actuator until the holes are aligned. Be aware of the specifications of each type of valve. Check valve brass, swing, threaded, ti3 the nibco brass swing check valve prevents backflow by automatically closing when fluid reverses direction. Inspection of valve during operation is recommended so that outside linkage can be.
Valves can be categorized also based on their function. As part of the crane valve group, crane supply is the exclusive distributor of crane brands in canada. Ball valves, fittings, valves, actuation, press system, pex, chemtrol, pcv. Installation,operation and maintenance manual swing check valve 3 3 general instructions for transportation, unpacking and storage when suspending and supporting a valve, take care and do not. Its no secret that poorly maintained equipment doesnt last as long as it should. The inner path of the valve can be closed by operating the valve stem. Particular check valves perform additional services as follows.